full20_28299671x386_9597

Sequence Valve


Category: .
Used when one cylinder in a multi-cylinder application must advance before any other.

Application: Used when one cylinder in a multi-cylinder application must advance before any other.

Operation: Pump is connected to port “P” and separate cylinders to ports “A” and “B”. When pressure is applied to port “P”, cylinder “A” advances. Cylinder “B” will not advance until a predetermined pressure setting is reached in cylinder “A”. Pressure setting is adjustable from 500 to 8,000 psi with adjustment screw; factory preset at 1,000 psi. Has 3/8″ NPTF ports.

Order No. Cylinder
Application *
Operation Valve Type Volt Advance / Return Advance / Hold Return Posi-Check® Feature Weight (lbs)
9597 S.A. & D.A. Automatic Sequence Valve — — — — 5.6
* “S.A.” represents single-acting cylinders, “D.A.” represents double-acting cylinders
Sequence Valve (9597) – Diagram
Catalog

Related Products

  • full20_31213671x386_INLine9580

    One-way Check Valve

  • full20_33615Valve9506

    4-Way, 3-Position (Tandem Ctr) Valve w/Posi-Check

  • full20_31199671x386_9592

    3/4-way, 2-position Solenoid

  • full20_28404671x386_9504

    3/4-way, 2-position Manual